Tripp-Lite Uninterruptible Power Supply SU3000LCD2UHV 2U SmartOnline 208-240V 3kVA 2.7kW USB

Tripp Lite
Availability:

Out of stock


$2,143.95

Out of stock

High-performance on-line double-conversion UPS with interactive LCD interface ideal for any critical voice, data, medical or industrial IT application. Converts AC input to DC and then to fully regulated sine wave AC power.
Protects Mission-Critical Rack-Mounted Equipment
●Converts AC input to DC power, then DC to fully regulated sine wave AC output
●+/-2% voltage regulation in online and battery modes
●Selectable 200/208/220/230/240V output voltage
●3000VA/2700W capacity
●6 NEMA 6-15/20R and 2 NEMA L6-20R outlets
●570-joule surge suppression rating
Interactive Front-Panel LCD
●Reports detailed status information, including load and battery levels
●Offers advanced configuration options, including output voltage and power strategies
5 Power Strategies
●Auto Adaptive enables high efficiency and high-quality operation as necessary for ideal equipment protection
●Max Efficiency favors economy operation with high 95% efficiency
●Max Quality favors on-line, double-conversion mode, maintaining +/-2% output voltage regulation and zero transfer time
●Frequency Regulation and Frequency Conversion enable +/-0.05 Hz output regulation for selected frequency (50/60 Hz)
Reliable, Expandable Battery Backup
●Supports half load (1350W) for 13.5 min. and full load (2700W) for 5 min.
●Add external battery packs for extra runtime
●“Smart” battery packs, such as Tripp Lite’s BP72V18-2US, are automatically sensed and configured during replacement
●Full 2700W capacity available with and without external battery packs
●Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries
Electronic Bypass
●Maintains utility output during UPS fault conditions
●Adjustable bypass range and high-efficiency mode voltage settings
Highly Customizable
ENERGY STAR Certification
Optional Network Management Cards
OUTPUT
– Output Volt Amp Capacity (VA):
3000
– Output kVA Capacity (kVA):
3
– Output Watt Capacity (Watts):
2700
– Output kW Capacity (kW):
2.7
– Output Capacity Details:
DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages, Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
– Power Factor:
0.9
– Crest Factor:
3:1
– Nominal Output Voltage(s) Supported:
200V, 208V, 220V, 230V, 240V
– Nominal Voltage Details:
Nominal output voltage is user configured on first power-on
– Frequency Compatibility:
50 / 60 Hz, Supports 50 to 60 Hz and 60 to 50 Hz conversion
– Frequency Compatibility Details:
Output frequency matches input nominal on startup, Output capacity de-rates by 30% during frequency conversion operation
– Output Voltage Regulation (Line Mode):
+/- 2%
– Output Voltage Regulation (Economy Line Mode):
+/- 10%
– Output Voltage Regulation (Battery Mode):
+/- 2%
– Output Receptacles:
(6) 6-15/20R, (2) L6-20R
– Load Management Receptacles:
Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)
– Output AC Waveform (AC Mode):
Pure Sine wave
– Output AC Waveform (Battery Mode):
Pure Sine wave
– Individually Controllable Load Banks:
Yes
INPUT
– Rated input current (Maximum Load):
14.97A
– Nominal Input Voltage(s) Supported:
200V AC, 208V AC, 220V AC, 230V AC, 240V AC
– UPS Input Connection Type:
L6-20P
– UPS Input Cord Length (ft.):
10
– UPS Input Cord Length (m):
3.1
– Recommended Electrical Service:
208/240V 20A
– Input Phase:
Single-Phase
BATTERY
– Full Load Runtime (min.):
5 min. (2700w)
– Half Load Runtime (min.):
13.5 min. (1350w)
– Expandable Battery Runtime:
Supports extended runtime with optional external battery packs
– External Battery Pack Compatibility:
BP72V15-2U (limit 1), BP72V28RT-3U (multi-pack compatible), BP72V18-2US (multi-pack compatible)
– DC System Voltage (VDC):
72
– Battery Recharge Rate (Included Batteries):
3.0 hours from 10% to 90% (typical, full load discharge)
– Internal UPS Replacement Battery Cartridge:
RBC72S
– Battery Access:
Front panel battery access door
– Battery Replacement Description:
Hot-swappable, replaceable batteries
– Expandable Runtime:
Yes
VOLTAGE REGULATION
– Voltage Regulation Description:
Online, double-conversion power conditioning
– Overvoltage Correction:
2% output voltage regulation during overvoltages to 288
– Undervoltage Correction:
2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS and CONTROLS
– Front Panel LCD Display:
Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information, LCD interface also enables a variety of advanced UPS setup and configuration options
– Switches:
5 front panel switches: On/Off, Up, Down and Escape
– Alarm Cancel Operation:
Power-fail alarm can be silenced by following on-screen prompts
– Audible Alarm:
Audible alarm indicates power failure, low battery, overload and fault
– LED Indicators:
4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
SURGE / NOISE SUPPRESSION
– UPS Dataline Suppression Details:
Single line dialup / network dataline protection included
– EMI / RFI AC Noise Suppression:
Yes
– AC Suppression Joule Rating:
570
– AC Suppression Response Time:
Instantaneous
PHYSICAL
– Included Mounting Accessory Description:
4 post installation accessories included
– Installation Form Factors Supported with Included Accessories:
4 post 19 inch rackmount
– Installation Form Factors Supported with Optional Accessories:
2 post rackmount (2POSTRMKITWM), Tower (2-9USTAND)
– Primary Form Factor:
Rackmount
– Rack Height (U Spaces):
2
– Cooling Method:
Fan
– UPS Housing Material:
Metal
ENVIRONMENTAL
– Operating Temperature Range:
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
– Storage Temperature Range:
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
– Relative Humidity:
5 to 95%, non-condensing
– AC Mode BTU / Hr. (Full Load):
933
– AC Economy Mode BTU / Hr. (Full Load):
588
– Battery Mode BTU / Hr. (Full Load):
1399
– AC Mode Efficiency Rating (100% Load):
>90%
– AC Economy Mode Efficiency Rating (100% Load):
>95%
– Audible Noise:
<50dB at front side 1M
COMMUNICATIONS
– Communications Interface:
USB (HID enabled), DB9 Serial, Contact closure, EPO (emergency power off), Slot for SNMP/Web interface
– Network Management Cards:
SNMPWEBCARD, WEBCARDLX
– Network Monitoring Port Description:
Supports detailed monitoring of UPS and site power conditions, DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations
– PowerAlert Software:
For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
– Communications Cable:
USB and DB9 cabling included
– WatchDog Compatibility:
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
– Transfer Time:
No transfer time (0 ms.) in online, double-conversion mode, 4 ms. transfer time during economy mode operation
– Low Voltage Transfer to Battery Power (Setpoint):
160V (100% load), 140V (66% load), 120V (33% load)
– High Voltage Transfer to Battery Power (Setpoint):
288V
SPECIAL FEATURES
– Grounding Lug:
Back panel grounding lug included
– Cold Start (Startup in Battery Mode During a Power Failure):
Cold-start operation supported
– High Availability UPS Features:
Automatic inverter bypass, Hot swappable batteries
– Green Energy-Saving Features:
High efficiency economy mode operation, Individually controllable load banks
CERTIFICATIONS
– UPS Certifications:
ENERGY STAR Qualified, Meets FCC Part 15 Category A (EMI), Tested to CSA (Canada), Tested to NOM (Mexico), Tested to UL1778 (USA)
Package Includes
SU3000LCD2UHV SmartOnline 3000VA/2700W On-Line Double-Conversion UPS
4-post rack-mount installation kit
USB cable
RS-232 cable
Owners manual
Item Dimension (L inchxW inchxH inch)
10 x 24 x 30
Weight
86.02lb
Warranty Information
2-year limited warranty

SKU: AS222019 Categories: , ,

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Tripp-Lite Uninterruptible Power Supply SU3000LCD2UHV 2U SmartOnline 208-240V 3kVA 2.7kW USB”